lastID = -296480
Skip to main content Skip to top navigation Skip to site search
Top of page
  • My citations options
    Web Back (from Web)
    Chicago Back (from Chicago)
    MLA Back (from MLA)
Close action menu

You need to login to use this feature.

Please wait a moment…
Please wait while we update your results...
Please wait a moment...
Description: Access Water
Context Menu
Description: Book cover
Okaloosa County's Transition to UV Disinfection
  • Browse
  • Compilations
    • Compilations list
  • Subscriptions
Tools

Related contents

Loading related content

Workflow

No linked records yet

X
  • Current: 2022-06-14 20:07:18 Adam Phillips
  • 2022-06-14 20:07:17 Adam Phillips
  • 2020-03-26 22:48:14 Adam Phillips
  • 2020-03-26 22:48:13 Adam Phillips
  • 2020-02-01 02:19:06 Administrator
  • 2020-02-01 02:19:05 Administrator
Description: Access Water
  • Browse
  • Compilations
  • Subscriptions
Log in
0
Accessibility Options

Base text size -

This is a sample piece of body text
Larger
Smaller
  • Shopping basket (0)
  • Accessibility options
  • Return to previous
Description: Book cover
Okaloosa County's Transition to UV Disinfection

Okaloosa County's Transition to UV Disinfection

Okaloosa County's Transition to UV Disinfection

  • New
  • View
  • Details
  • Reader
  • Default
  • Share
  • Email
  • Facebook
  • Twitter
  • LinkedIn
  • New
  • View
  • Default view
  • Reader view
  • Data view
  • Details

This page cannot be printed from here

Please use the dedicated print option from the 'view' drop down menu located in the blue ribbon in the top, right section of the publication.

screenshot of print menu option

Description: Book cover
Okaloosa County's Transition to UV Disinfection
Abstract
Population growth and increased attention on water quality are forcing communities to increasingly look to reclaimed water for landscape irrigation to offset potable demand. Due to the requirements to provide high level disinfection with a chlorine residual for public access reuse, use of UV disinfection is limited, because it would have to be supplemented with chlorine disinfection. Operating two disinfection systems is prohibitive from both a cost and operations stand-point at most facilities. However, in certain circumstances the use of UV disinfection can be a feasible disinfection alternative.The new Okaloosa County Arbennie Pritchett Water Reclamation Facility (WRF) presents a situation where UV disinfection is the ideal alternative. Located in the Florida panhandle, Okaloosa County is currently served by the aging Garniers wastewater treatment plant. Due to a number of odor issues and the residential location of the Garniers plant, the County commissioned the Arbennie Pritchett WRF to be constructed on the site of its existing effluent spray fields, property leased from Eglin Air Force Base. Several new rapid infiltration basins (RIBs) have been constructed for effluent disposal in the immediate vicinity of the plant. Because no public access is currently planned for the Arbennie Pritchett WRF, effluent limits for the RIBs system are considerably less stringent than for areas with public access. No chlorine residual is required per the facility's permit from the Florida Department of Environmental Protection (FDEP).While the Garniers plant currently uses chlorine gas for disinfection, it was not a practical option for the Arbennie Pritchett WRF. Due to increasing regulations and safety issues related to the use of chlorine gas and concerns expressed by the Air Force regarding chlorine gas on base, UV disinfection was determined to be the best alternative for the Arbennie Pritchett WRF. The facility includes a four-stage Bardenpho Carrousel® process with secondary clarifiers and a UV disinfection system, with provisions for future installation of cloth-disk filters prior to the UV disinfection system included in the design. Disinfected effluent flows into a wet well where it is pumped to the RIBs system.Considering the effluent disposal location and permit requirements, UV disinfection was selected as the preferred alternative at the Arbennie Pritchett WRF. The UV disinfection system is sized for an average daily flow of 10 MGD and is readily expandable to 15 MGD to meet projected future demand. The UV modules will be installed in two concrete channels, with a third empty channel available for the expansion. Design parameters for the system include 65 percent UV transmittance without the presence of filters, and an effluent limit of 200 fecal coliforms per 100 mL, per Florida Statute 62–600. Additionally, the absence of chlorine addition and associated disinfection by-products provides a major advantage over chlorine disinfection.This paper will discuss the disinfection alternatives evaluated as well as the selection of UV disinfection for the Okaloosa County Arbennie Pritchett WRF. This paper will also highlight the differences between chlorine and UV disinfection systems and the reasons behind selecting one over the other.
Population growth and increased attention on water quality are forcing communities to increasingly look to reclaimed water for landscape irrigation to offset potable demand. Due to the requirements to provide high level disinfection with a chlorine residual for public access reuse, use of UV disinfection is limited, because it would have to be supplemented with chlorine disinfection. Operating two...
Author(s)
Michael ScullionDavid KozanRobert Mauzy
SourceProceedings of the Water Environment Federation
SubjectSession 3 - UV Design
Document typeConference Paper
PublisherWater Environment Federation
Print publication date Jan, 2009
ISSN1938-6478
SICI1938-6478(20090101)2009:1L.90;1-
DOI10.2175/193864709793847735
Volume / Issue2009 / 1
Content sourceDisinfection and Reuse Symposium
First / last page(s)90 - 99
Copyright2009
Word count502
Subject keywordsUV disinfectionreclaimed waterwater reuseRIBs

Purchase price $11.50

Get access
Log in Purchase content Purchase subscription
You may already have access to this content if you have previously purchased this content or have a subscription.
Need to create an account?

You can purchase access to this content but you might want to consider a subscription for a wide variety of items at a substantial discount!

Purchase access to 'Okaloosa County's Transition to UV Disinfection'

Add to cart
Purchase a subscription to gain access to 18,000+ Proceeding Papers, 25+ Fact Sheets, 20+ Technical Reports, 50+ magazine articles and select Technical Publications' chapters.
Loading items
There are no items to display at the moment.
Something went wrong trying to load these items.
Description: Book cover
Okaloosa County's Transition to UV Disinfection
Pricing
Non-member price: $11.50
Member price:
-296480
Get access
-296480
Log in Purchase content Purchase subscription
You may already have access to this content if you have previously purchased this content or have a subscription.
Need to create an account?

You can purchase access to this content but you might want to consider a subscription for a wide variety of items at a substantial discount!

Purchase access to 'Okaloosa County's Transition to UV Disinfection'

Add to cart
Purchase a subscription to gain access to 18,000+ Proceeding Papers, 25+ Fact Sheets, 20+ Technical Reports, 50+ magazine articles and select Technical Publications' chapters.

Details

Description: Book cover
Okaloosa County's Transition to UV Disinfection
Abstract
Population growth and increased attention on water quality are forcing communities to increasingly look to reclaimed water for landscape irrigation to offset potable demand. Due to the requirements to provide high level disinfection with a chlorine residual for public access reuse, use of UV disinfection is limited, because it would have to be supplemented with chlorine disinfection. Operating two disinfection systems is prohibitive from both a cost and operations stand-point at most facilities. However, in certain circumstances the use of UV disinfection can be a feasible disinfection alternative.The new Okaloosa County Arbennie Pritchett Water Reclamation Facility (WRF) presents a situation where UV disinfection is the ideal alternative. Located in the Florida panhandle, Okaloosa County is currently served by the aging Garniers wastewater treatment plant. Due to a number of odor issues and the residential location of the Garniers plant, the County commissioned the Arbennie Pritchett WRF to be constructed on the site of its existing effluent spray fields, property leased from Eglin Air Force Base. Several new rapid infiltration basins (RIBs) have been constructed for effluent disposal in the immediate vicinity of the plant. Because no public access is currently planned for the Arbennie Pritchett WRF, effluent limits for the RIBs system are considerably less stringent than for areas with public access. No chlorine residual is required per the facility's permit from the Florida Department of Environmental Protection (FDEP).While the Garniers plant currently uses chlorine gas for disinfection, it was not a practical option for the Arbennie Pritchett WRF. Due to increasing regulations and safety issues related to the use of chlorine gas and concerns expressed by the Air Force regarding chlorine gas on base, UV disinfection was determined to be the best alternative for the Arbennie Pritchett WRF. The facility includes a four-stage Bardenpho Carrousel® process with secondary clarifiers and a UV disinfection system, with provisions for future installation of cloth-disk filters prior to the UV disinfection system included in the design. Disinfected effluent flows into a wet well where it is pumped to the RIBs system.Considering the effluent disposal location and permit requirements, UV disinfection was selected as the preferred alternative at the Arbennie Pritchett WRF. The UV disinfection system is sized for an average daily flow of 10 MGD and is readily expandable to 15 MGD to meet projected future demand. The UV modules will be installed in two concrete channels, with a third empty channel available for the expansion. Design parameters for the system include 65 percent UV transmittance without the presence of filters, and an effluent limit of 200 fecal coliforms per 100 mL, per Florida Statute 62–600. Additionally, the absence of chlorine addition and associated disinfection by-products provides a major advantage over chlorine disinfection.This paper will discuss the disinfection alternatives evaluated as well as the selection of UV disinfection for the Okaloosa County Arbennie Pritchett WRF. This paper will also highlight the differences between chlorine and UV disinfection systems and the reasons behind selecting one over the other.
Population growth and increased attention on water quality are forcing communities to increasingly look to reclaimed water for landscape irrigation to offset potable demand. Due to the requirements to provide high level disinfection with a chlorine residual for public access reuse, use of UV disinfection is limited, because it would have to be supplemented with chlorine disinfection. Operating two...
Author(s)
Michael ScullionDavid KozanRobert Mauzy
SourceProceedings of the Water Environment Federation
SubjectSession 3 - UV Design
Document typeConference Paper
PublisherWater Environment Federation
Print publication date Jan, 2009
ISSN1938-6478
SICI1938-6478(20090101)2009:1L.90;1-
DOI10.2175/193864709793847735
Volume / Issue2009 / 1
Content sourceDisinfection and Reuse Symposium
First / last page(s)90 - 99
Copyright2009
Word count502
Subject keywordsUV disinfectionreclaimed waterwater reuseRIBs

Actions, changes & tasks

Outstanding Actions

Add action for paragraph

Current Changes

Add signficant change

Current Tasks

Add risk task

Connect with us

Follow us on Facebook
Follow us on Twitter
Connect to us on LinkedIn
Subscribe on YouTube
Powered by Librios Ltd
Powered by Librios Ltd
Authors
Terms of Use
Policies
Help
Accessibility
Contact us
Copyright © 2024 by the Water Environment Federation
Loading items
There are no items to display at the moment.
Something went wrong trying to load these items.
Description: WWTF Digital Boot 180x150
WWTF Digital (180x150)
Created on Jul 02
Websitehttps:/­/­www.wef.org/­wwtf?utm_medium=WWTF&utm_source=AccessWater&utm_campaign=WWTF
180x150
Michael Scullion# David Kozan# Robert Mauzy. Okaloosa County's Transition to UV Disinfection. Alexandria, VA 22314-1994, USA: Water Environment Federation, 2018. Web. 1 Jul. 2025. <https://www.accesswater.org?id=-296480CITANCHOR>.
Michael Scullion# David Kozan# Robert Mauzy. Okaloosa County's Transition to UV Disinfection. Alexandria, VA 22314-1994, USA: Water Environment Federation, 2018. Accessed July 1, 2025. https://www.accesswater.org/?id=-296480CITANCHOR.
Michael Scullion# David Kozan# Robert Mauzy
Okaloosa County's Transition to UV Disinfection
Access Water
Water Environment Federation
December 22, 2018
July 1, 2025
https://www.accesswater.org/?id=-296480CITANCHOR