lastID = -297204
Skip to main content Skip to top navigation Skip to site search
Top of page
  • My citations options
    Web Back (from Web)
    Chicago Back (from Chicago)
    MLA Back (from MLA)
Close action menu

You need to login to use this feature.

Please wait a moment…
Please wait while we update your results...
Please wait a moment...
Description: Access Water
Context Menu
Description: Book cover
PRI-SC® Sulfide, Phosphorus and UV Fouling Improvements at Raleigh, NC
  • Browse
  • Compilations
    • Compilations list
  • Subscriptions
Tools

Related contents

Loading related content

Workflow

No linked records yet

X
  • Current: 2020-02-01 03:12:25 Administrator
  • 2020-02-01 03:12:24 Administrator
Description: Access Water
  • Browse
  • Compilations
  • Subscriptions
Log in
0
Accessibility Options

Base text size -

This is a sample piece of body text
Larger
Smaller
  • Shopping basket (0)
  • Accessibility options
  • Return to previous
Description: Book cover
PRI-SC® Sulfide, Phosphorus and UV Fouling Improvements at Raleigh, NC

PRI-SC® Sulfide, Phosphorus and UV Fouling Improvements at Raleigh, NC

PRI-SC® Sulfide, Phosphorus and UV Fouling Improvements at Raleigh, NC

  • New
  • View
  • Details
  • Reader
  • Default
  • Share
  • Email
  • Facebook
  • Twitter
  • LinkedIn
  • New
  • View
  • Default view
  • Reader view
  • Data view
  • Details

This page cannot be printed from here

Please use the dedicated print option from the 'view' drop down menu located in the blue ribbon in the top, right section of the publication.

screenshot of print menu option

Description: Book cover
PRI-SC® Sulfide, Phosphorus and UV Fouling Improvements at Raleigh, NC
Abstract
The City of Raleigh has been using ferrous sulfate (FeSO4) for years in their collection system for hydrogen sulfide and plant phosphorus control. Several years ago the Neuse River wastewater treatment plant upgraded their ultraviolet disinfection (UV) system to a higher intensity lamp technology. Although the UV system was equipped with mecha ical wipers, manual cleaning by plant personnel was required due to the elevated iron levels carrying over to the disinfection stage coupled with the lamp sleeve's higher temperature. In 2008, the City of Raleigh implemented Peroxide Regenerated Iron Sulfide Control (PRI-SC®) as a means to improve collection system sulfide control and maintain plant phosphorus removal while reducing the amount of iron salts in the collection system. PRI-SC® chemical savings were found to be 80,300 per year. Manual UV sleeve cleaning frequency was reduced from 2 weeks to 2 months, saving 32 man hours per cleaning or 25,600 per year
The City of Raleigh has been using ferrous sulfate (FeSO4) for years in their collection system for hydrogen sulfide and plant phosphorus control. Several years ago the Neuse River wastewater treatment plant upgraded their ultraviolet disinfection (UV) system to a higher intensity lamp technology. Although the UV system was equipped with mecha ical wipers, manual cleaning by plant personnel was...
Author(s)
Paris NeofotistosGeorge DeshinskyT.J. LynchTim Keene
SourceProceedings of the Water Environment Federation
SubjectSession 62: Developments in Process Design
Document typeConference Paper
PublisherWater Environment Federation
Print publication date Jan, 2010
ISSN1938-6478
SICI1938-6478(20100101)2010:12L.4323;1-
DOI10.2175/193864710798182718
Volume / Issue2010 / 12
Content sourceWEFTEC
First / last page(s)4323 - 4335
Copyright2010
Word count161
Subject keywordsHydrogen SulfidePRI-SC®Hydrogen PeroxideIron SaltsAlumOdor ControlPhosphorusUltraviolet Disinfection

Purchase price $11.50

Get access
Log in Purchase content Purchase subscription
You may already have access to this content if you have previously purchased this content or have a subscription.
Need to create an account?

You can purchase access to this content but you might want to consider a subscription for a wide variety of items at a substantial discount!

Purchase access to 'PRI-SC® Sulfide, Phosphorus and UV Fouling Improvements at Raleigh, NC'

Add to cart
Purchase a subscription to gain access to 18,000+ Proceeding Papers, 25+ Fact Sheets, 20+ Technical Reports, 50+ magazine articles and select Technical Publications' chapters.
Loading items
There are no items to display at the moment.
Something went wrong trying to load these items.
Description: Book cover
PRI-SC® Sulfide, Phosphorus and UV Fouling Improvements at Raleigh, NC
Pricing
Non-member price: $11.50
Member price:
-297204
Get access
-297204
Log in Purchase content Purchase subscription
You may already have access to this content if you have previously purchased this content or have a subscription.
Need to create an account?

You can purchase access to this content but you might want to consider a subscription for a wide variety of items at a substantial discount!

Purchase access to 'PRI-SC® Sulfide, Phosphorus and UV Fouling Improvements at Raleigh, NC'

Add to cart
Purchase a subscription to gain access to 18,000+ Proceeding Papers, 25+ Fact Sheets, 20+ Technical Reports, 50+ magazine articles and select Technical Publications' chapters.

Details

Description: Book cover
PRI-SC® Sulfide, Phosphorus and UV Fouling Improvements at Raleigh, NC
Abstract
The City of Raleigh has been using ferrous sulfate (FeSO4) for years in their collection system for hydrogen sulfide and plant phosphorus control. Several years ago the Neuse River wastewater treatment plant upgraded their ultraviolet disinfection (UV) system to a higher intensity lamp technology. Although the UV system was equipped with mecha ical wipers, manual cleaning by plant personnel was required due to the elevated iron levels carrying over to the disinfection stage coupled with the lamp sleeve's higher temperature. In 2008, the City of Raleigh implemented Peroxide Regenerated Iron Sulfide Control (PRI-SC®) as a means to improve collection system sulfide control and maintain plant phosphorus removal while reducing the amount of iron salts in the collection system. PRI-SC® chemical savings were found to be 80,300 per year. Manual UV sleeve cleaning frequency was reduced from 2 weeks to 2 months, saving 32 man hours per cleaning or 25,600 per year
The City of Raleigh has been using ferrous sulfate (FeSO4) for years in their collection system for hydrogen sulfide and plant phosphorus control. Several years ago the Neuse River wastewater treatment plant upgraded their ultraviolet disinfection (UV) system to a higher intensity lamp technology. Although the UV system was equipped with mecha ical wipers, manual cleaning by plant personnel was...
Author(s)
Paris NeofotistosGeorge DeshinskyT.J. LynchTim Keene
SourceProceedings of the Water Environment Federation
SubjectSession 62: Developments in Process Design
Document typeConference Paper
PublisherWater Environment Federation
Print publication date Jan, 2010
ISSN1938-6478
SICI1938-6478(20100101)2010:12L.4323;1-
DOI10.2175/193864710798182718
Volume / Issue2010 / 12
Content sourceWEFTEC
First / last page(s)4323 - 4335
Copyright2010
Word count161
Subject keywordsHydrogen SulfidePRI-SC®Hydrogen PeroxideIron SaltsAlumOdor ControlPhosphorusUltraviolet Disinfection

Actions, changes & tasks

Outstanding Actions

Add action for paragraph

Current Changes

Add signficant change

Current Tasks

Add risk task

Connect with us

Follow us on Facebook
Follow us on Twitter
Connect to us on LinkedIn
Subscribe on YouTube
Powered by Librios Ltd
Powered by Librios Ltd
Authors
Terms of Use
Policies
Help
Accessibility
Contact us
Copyright © 2024 by the Water Environment Federation
Loading items
There are no items to display at the moment.
Something went wrong trying to load these items.
Description: WWTF Digital Boot 180x150
WWTF Digital (180x150)
Created on Jul 02
Websitehttps:/­/­www.wef.org/­wwtf?utm_medium=WWTF&utm_source=AccessWater&utm_campaign=WWTF
180x150
Paris Neofotistos# George Deshinsky# T.J. Lynch# Tim Keene. PRI-SC® Sulfide, Phosphorus and UV Fouling Improvements at Raleigh, NC. Alexandria, VA 22314-1994, USA: Water Environment Federation, 2018. Web. 15 Oct. 2025. <https://www.accesswater.org?id=-297204CITANCHOR>.
Paris Neofotistos# George Deshinsky# T.J. Lynch# Tim Keene. PRI-SC® Sulfide, Phosphorus and UV Fouling Improvements at Raleigh, NC. Alexandria, VA 22314-1994, USA: Water Environment Federation, 2018. Accessed October 15, 2025. https://www.accesswater.org/?id=-297204CITANCHOR.
Paris Neofotistos# George Deshinsky# T.J. Lynch# Tim Keene
PRI-SC® Sulfide, Phosphorus and UV Fouling Improvements at Raleigh, NC
Access Water
Water Environment Federation
December 22, 2018
October 15, 2025
https://www.accesswater.org/?id=-297204CITANCHOR