lastID = -297400
Skip to main content Skip to top navigation Skip to site search
Top of page
  • My citations options
    Web Back (from Web)
    Chicago Back (from Chicago)
    MLA Back (from MLA)
Close action menu

You need to login to use this feature.

Please wait a moment…
Please wait while we update your results...
Please wait a moment...
Description: Access Water
Context Menu
Description: Book cover
Development of a Dynamic Wastewater Treatment Plant Hydraulic Model Linked with Collection System
  • Browse
  • Compilations
    • Compilations list
  • Subscriptions
Tools

Related contents

Loading related content

Workflow

No linked records yet

X
  • Current: 2020-01-31 21:57:45 Administrator
  • 2020-01-31 21:57:44 Administrator
Description: Access Water
  • Browse
  • Compilations
  • Subscriptions
Log in
0
Accessibility Options

Base text size -

This is a sample piece of body text
Larger
Smaller
  • Shopping basket (0)
  • Accessibility options
  • Return to previous
Description: Book cover
Development of a Dynamic Wastewater Treatment Plant Hydraulic Model Linked with Collection System

Development of a Dynamic Wastewater Treatment Plant Hydraulic Model Linked with Collection System

Development of a Dynamic Wastewater Treatment Plant Hydraulic Model Linked with Collection System

  • New
  • View
  • Details
  • Reader
  • Default
  • Share
  • Email
  • Facebook
  • Twitter
  • LinkedIn
  • New
  • View
  • Default view
  • Reader view
  • Data view
  • Details

This page cannot be printed from here

Please use the dedicated print option from the 'view' drop down menu located in the blue ribbon in the top, right section of the publication.

screenshot of print menu option

Description: Book cover
Development of a Dynamic Wastewater Treatment Plant Hydraulic Model Linked with Collection System
Abstract
Currently, the City of Atlanta serves approximately 1,600 miles of sewer mains (15% combined and 85% separated) in 132 square miles area. All sewage flow within the City is treated by four wastewater treatment facilities and four combined sewage overflow (CSO) control facilities to serve a population of 1.6 million with a total average daily flow of 182 MGD. In addition to the flow produced within the City, there are six adjoining municipalities contributing flow to the City of Atlanta sewer system that comprise 45% of the total flow.In response to the First Amended Consent Decree issued from the US Environmental Protection Agency (EPA) and Georgia Environmental Protection Division (EPD), the City of Atlanta began to build a comprehensive, dynamic hydraulic model of its sewer system. The City sanitary system was divided into ten sewer basins based on the natural boundaries of the collection system and the wastewater service areas. Each of the sewer basin model has a free outfall at the last node to represent the wastewater treatment facility.While evaluating the existing conveyance system and ensuring that it is sufficient to carry future dry weather flows and peak wet weather flows, the City is mindful not to allow the peaks at the free outfalls to exceed the design capacity of the corresponding treatment facility. The City currently has a static spreadsheet hydraulic model of each wastewater treatment facility that is not linked to the sewer hydraulic model. The City's static spreadsheet model has many limitations including single pass flow simulation, no calculation for backwater surcharging, limited “what if” scenario analysis capability for plant operation, maintenance and planning, and no real-time simulation mode option.The objective of the study was to develop a dynamic hydraulic model for Utoy Creek Water Reclamation Center (WRC) linking with the existing sewer hydraulic model. InfoWorks CS was chosen as the software package to model the treatment facility as the City's collection system uses the same software. Utoy Creek WRC is the newest of the four treatment facilities in Atlanta and includes bar screens, drum screens, primary clarifiers, activated sludge with biological phosphorus removal (BPR), secondary clarifiers with return activated sludge (RAS) pumps, tertiary filters, UV disinfection and a staged effluent channel with a peak day plant design capacity of 74 MGD.InfoWorks lends itself well to this application as it has some physical parameters that represent actual operations and processes in treatment facilities. Bar Screens and drum screens are link options in the software that were tailored to replicate the actual screen parameters. Primary and secondary clarifiers were set up as storage nodes and weirs, while the biological phosphorus removal (BPR) tanks and conveyance systems were setup as open rectangular channels and circular pipes. The process for preparing testing and calibrating this treatment facility model consisted of identifying the physical components and data from the treatment plant within Infoworks and obtaining actual flow data to compare to the simulation model results.One of the challenges of modeling the treatment facility is the multiple real time controls (RTC)s required for adapting the system's variable frequency drive (VFD) pumps to adjust to fluctuations in the flow volume. Infoworks CS has the RTC control capability to handle various complex scenarios such as these.After a preliminary model was setup based on the physical and hydraulic characteristics of the plant, flow verification and model calibration was required. This process was setup by installing an additional meter to monitor the effluent flow from the plant and survey benchmarks at critical locations to measure depth of flow in the miscellaneous processes. On a typical dry weather day (no rain for the three proceeding days), flow depths were measured and times noted at all benchmarks. The plant's supervisory control and data acquisition (SCADA) information was also collected to identify how many units within each process were in operation together with pump flows and wet well depths. Continuous level recorders were also installed at several locations to monitor the flow depth variations during daily flow fluctuations and rainfall storm events. A comparison of measured depth to modeled depth was used to adjust headlosses in the model to reflect the field data.The development of this dynamic hydraulic model has numerous applications. The static model was originally used as a tool for permitting or for design of planned facility upgrades. The dynamic model can be used to plan maintenance procedures and to see the effects of taking parts of processes offline as well as show the effects of unplanned process failure due to power outages. The model also helps predict changes in plant flow due to discharge point river level fluctuations and backwater effect. Additionally, the dynamic model created in a widely used software package would have the advantage that it only needs to be created once and could be utilized and understood by the users at the City as well as by any consultant as necessary whereas the static model was recreated each time new upgrades were planned. In the long-term, the other three WRCs will also be modeled and merged with the conveyance system to produce a truly integrated flow model which will be very unique tool for modeling applications in wastewater industry.
Currently, the City of Atlanta serves approximately 1,600 miles of sewer mains (15% combined and 85% separated) in 132 square miles area. All sewage flow within the City is treated by four wastewater treatment facilities and four combined sewage overflow (CSO) control facilities to serve a population of 1.6 million with a total average daily flow of 182 MGD. In addition to the flow produced within...
Author(s)
Rasheed AhmadKai IaukeaAlberto BecharaVahe KokorianMichael ShelhamerDavid Winters
SourceProceedings of the Water Environment Federation
SubjectSession 34: Advances in Process Control and Automation
Document typeConference Paper
PublisherWater Environment Federation
Print publication date Jan, 2010
ISSN1938-6478
SICI1938-6478(20100101)2010:15L.2063;1-
DOI10.2175/193864710798159372
Volume / Issue2010 / 15
Content sourceWEFTEC
First / last page(s)2063 - 2064
Copyright2010
Word count872
Subject keywordsWastewater treatment planthydraulic modelingInfoworks CSRTC

Purchase price $11.50

Get access
Log in Purchase content Purchase subscription
You may already have access to this content if you have previously purchased this content or have a subscription.
Need to create an account?

You can purchase access to this content but you might want to consider a subscription for a wide variety of items at a substantial discount!

Purchase access to 'Development of a Dynamic Wastewater Treatment Plant Hydraulic Model Linked with Collection System'

Add to cart
Purchase a subscription to gain access to 18,000+ Proceeding Papers, 25+ Fact Sheets, 20+ Technical Reports, 50+ magazine articles and select Technical Publications' chapters.
Loading items
There are no items to display at the moment.
Something went wrong trying to load these items.
Description: Book cover
Development of a Dynamic Wastewater Treatment Plant Hydraulic Model Linked with Collection System
Pricing
Non-member price: $11.50
Member price:
-297400
Get access
-297400
Log in Purchase content Purchase subscription
You may already have access to this content if you have previously purchased this content or have a subscription.
Need to create an account?

You can purchase access to this content but you might want to consider a subscription for a wide variety of items at a substantial discount!

Purchase access to 'Development of a Dynamic Wastewater Treatment Plant Hydraulic Model Linked with Collection System'

Add to cart
Purchase a subscription to gain access to 18,000+ Proceeding Papers, 25+ Fact Sheets, 20+ Technical Reports, 50+ magazine articles and select Technical Publications' chapters.

Details

Description: Book cover
Development of a Dynamic Wastewater Treatment Plant Hydraulic Model Linked with Collection System
Abstract
Currently, the City of Atlanta serves approximately 1,600 miles of sewer mains (15% combined and 85% separated) in 132 square miles area. All sewage flow within the City is treated by four wastewater treatment facilities and four combined sewage overflow (CSO) control facilities to serve a population of 1.6 million with a total average daily flow of 182 MGD. In addition to the flow produced within the City, there are six adjoining municipalities contributing flow to the City of Atlanta sewer system that comprise 45% of the total flow.In response to the First Amended Consent Decree issued from the US Environmental Protection Agency (EPA) and Georgia Environmental Protection Division (EPD), the City of Atlanta began to build a comprehensive, dynamic hydraulic model of its sewer system. The City sanitary system was divided into ten sewer basins based on the natural boundaries of the collection system and the wastewater service areas. Each of the sewer basin model has a free outfall at the last node to represent the wastewater treatment facility.While evaluating the existing conveyance system and ensuring that it is sufficient to carry future dry weather flows and peak wet weather flows, the City is mindful not to allow the peaks at the free outfalls to exceed the design capacity of the corresponding treatment facility. The City currently has a static spreadsheet hydraulic model of each wastewater treatment facility that is not linked to the sewer hydraulic model. The City's static spreadsheet model has many limitations including single pass flow simulation, no calculation for backwater surcharging, limited “what if” scenario analysis capability for plant operation, maintenance and planning, and no real-time simulation mode option.The objective of the study was to develop a dynamic hydraulic model for Utoy Creek Water Reclamation Center (WRC) linking with the existing sewer hydraulic model. InfoWorks CS was chosen as the software package to model the treatment facility as the City's collection system uses the same software. Utoy Creek WRC is the newest of the four treatment facilities in Atlanta and includes bar screens, drum screens, primary clarifiers, activated sludge with biological phosphorus removal (BPR), secondary clarifiers with return activated sludge (RAS) pumps, tertiary filters, UV disinfection and a staged effluent channel with a peak day plant design capacity of 74 MGD.InfoWorks lends itself well to this application as it has some physical parameters that represent actual operations and processes in treatment facilities. Bar Screens and drum screens are link options in the software that were tailored to replicate the actual screen parameters. Primary and secondary clarifiers were set up as storage nodes and weirs, while the biological phosphorus removal (BPR) tanks and conveyance systems were setup as open rectangular channels and circular pipes. The process for preparing testing and calibrating this treatment facility model consisted of identifying the physical components and data from the treatment plant within Infoworks and obtaining actual flow data to compare to the simulation model results.One of the challenges of modeling the treatment facility is the multiple real time controls (RTC)s required for adapting the system's variable frequency drive (VFD) pumps to adjust to fluctuations in the flow volume. Infoworks CS has the RTC control capability to handle various complex scenarios such as these.After a preliminary model was setup based on the physical and hydraulic characteristics of the plant, flow verification and model calibration was required. This process was setup by installing an additional meter to monitor the effluent flow from the plant and survey benchmarks at critical locations to measure depth of flow in the miscellaneous processes. On a typical dry weather day (no rain for the three proceeding days), flow depths were measured and times noted at all benchmarks. The plant's supervisory control and data acquisition (SCADA) information was also collected to identify how many units within each process were in operation together with pump flows and wet well depths. Continuous level recorders were also installed at several locations to monitor the flow depth variations during daily flow fluctuations and rainfall storm events. A comparison of measured depth to modeled depth was used to adjust headlosses in the model to reflect the field data.The development of this dynamic hydraulic model has numerous applications. The static model was originally used as a tool for permitting or for design of planned facility upgrades. The dynamic model can be used to plan maintenance procedures and to see the effects of taking parts of processes offline as well as show the effects of unplanned process failure due to power outages. The model also helps predict changes in plant flow due to discharge point river level fluctuations and backwater effect. Additionally, the dynamic model created in a widely used software package would have the advantage that it only needs to be created once and could be utilized and understood by the users at the City as well as by any consultant as necessary whereas the static model was recreated each time new upgrades were planned. In the long-term, the other three WRCs will also be modeled and merged with the conveyance system to produce a truly integrated flow model which will be very unique tool for modeling applications in wastewater industry.
Currently, the City of Atlanta serves approximately 1,600 miles of sewer mains (15% combined and 85% separated) in 132 square miles area. All sewage flow within the City is treated by four wastewater treatment facilities and four combined sewage overflow (CSO) control facilities to serve a population of 1.6 million with a total average daily flow of 182 MGD. In addition to the flow produced within...
Author(s)
Rasheed AhmadKai IaukeaAlberto BecharaVahe KokorianMichael ShelhamerDavid Winters
SourceProceedings of the Water Environment Federation
SubjectSession 34: Advances in Process Control and Automation
Document typeConference Paper
PublisherWater Environment Federation
Print publication date Jan, 2010
ISSN1938-6478
SICI1938-6478(20100101)2010:15L.2063;1-
DOI10.2175/193864710798159372
Volume / Issue2010 / 15
Content sourceWEFTEC
First / last page(s)2063 - 2064
Copyright2010
Word count872
Subject keywordsWastewater treatment planthydraulic modelingInfoworks CSRTC

Actions, changes & tasks

Outstanding Actions

Add action for paragraph

Current Changes

Add signficant change

Current Tasks

Add risk task

Connect with us

Follow us on Facebook
Follow us on Twitter
Connect to us on LinkedIn
Subscribe on YouTube
Powered by Librios Ltd
Powered by Librios Ltd
Authors
Terms of Use
Policies
Help
Accessibility
Contact us
Copyright © 2024 by the Water Environment Federation
Loading items
There are no items to display at the moment.
Something went wrong trying to load these items.
Description: WWTF Digital Boot 180x150
WWTF Digital (180x150)
Created on Jul 02
Websitehttps:/­/­www.wef.org/­wwtf?utm_medium=WWTF&utm_source=AccessWater&utm_campaign=WWTF
180x150
Rasheed Ahmad# Kai Iaukea# Alberto Bechara# Vahe Kokorian# Michael Shelhamer# David Winters. Development of a Dynamic Wastewater Treatment Plant Hydraulic Model Linked with Collection System. Alexandria, VA 22314-1994, USA: Water Environment Federation, 2018. Web. 12 Sep. 2025. <https://www.accesswater.org?id=-297400CITANCHOR>.
Rasheed Ahmad# Kai Iaukea# Alberto Bechara# Vahe Kokorian# Michael Shelhamer# David Winters. Development of a Dynamic Wastewater Treatment Plant Hydraulic Model Linked with Collection System. Alexandria, VA 22314-1994, USA: Water Environment Federation, 2018. Accessed September 12, 2025. https://www.accesswater.org/?id=-297400CITANCHOR.
Rasheed Ahmad# Kai Iaukea# Alberto Bechara# Vahe Kokorian# Michael Shelhamer# David Winters
Development of a Dynamic Wastewater Treatment Plant Hydraulic Model Linked with Collection System
Access Water
Water Environment Federation
December 22, 2018
September 12, 2025
https://www.accesswater.org/?id=-297400CITANCHOR